2.15.4. Installation of the fuel filter

To check sealing rings for existence of cuts, забоин or attritions. If necessary to replace rings.
1. To install the filter so that the arrow on its case corresponded to the direction of supply of fuel, and to fix the filter by a collar.
2. To attach fuel tubes to the filter, having tightened fastening nuts the moment (20–34) N · m.

       PREVENTION
It is obligatory to use the second key from the fuel filter when tightening nuts of fastening.

3. By means of giving of voltage of +12 V on contact of pGc of a block of diagnostics to include an electrogasoline pump and to be convinced of lack of leak of fuel.